Pedicle Breach Rate 6.2 Percent With 2D Fluoroscopy

Last Updated: June 20, 2012.

 

Technique safe for placement of pedicle screws during transforaminal lumbar interbody fusion

Share |

Comments: (0)

Tell-a-Friend

 

  Related
 
A two-dimensional fluoroscopic technique is safe for percutaneous placement of pedicle screws during transforaminal lumbar interbody fusion, with a pedicle breach rate of 6.2 percent, according to a study published online June 7 in the Journal of Spinal Disorders & Techniques.

WEDNESDAY, June 20 (HealthDay News) -- A two-dimensional (2D) fluoroscopic technique is safe for percutaneous placement of pedicle screws during transforaminal lumbar interbody fusion (TLIF), with a pedicle breach rate of 6.2 percent, according to a study published online June 7 in the Journal of Spinal Disorders & Techniques.

Zachary A. Smith, M.D., from Northwestern University in Chicago, and colleagues conducted a prospective study involving 151 patients (average age, 56.6 years) following instrumented single-level (129 cases) or two-level (22 cases) minimally-invasive TLIF. A total of 601 pedicle screws were used for percutaneous fixation, with placement guided by 2D fluoroscopy. Patients were followed for potential clinical symptoms, and radiographic results, including postoperative computed tomography scans, were analyzed.

The researchers observed 37 pedicle breaches in 601 instrumented pedicles (6.2 percent), with 22 significant breaches (≥3mm; 3.7 percent). The level of the breaches were L3 (five of 46; 10.2 percent), L4 (12 of 201; 7.0 percent), L5 (15 of 158; 9.5 percent), and S1 (three of 47; 3.4 percent). There were 22 medial breaches, 12 lateral, two superior, and one inferior. Two of the breaches were symptomatic; both were associated with a medial breach at the L5 pedicle. Symptoms were transient and neither breach required hardware repositioning.

"In the current study, we report a pedicle breach rate of 6.2 percent using a 2D fluoroscopic technique without computer assistance," the authors write. "While newer assistive technologies, including computer assisted fluoroscopy and the O-arm, may decrease occupational exposure, the accurate placement of pedicle screws can be undertaken without this technology."

One author disclosed financial ties to Medtronic.

Abstract
Full Text (subscription or payment may be required)

Copyright © 2012 HealthDay. All rights reserved.


Previous: Diabetes Linked to Increased Cause-Specific Mortality Next: Deep Brain Stimulation Aids Motor Function in Parkinson's

Reader comments on this article are listed below. Review our comments policy.


Submit your opinion:

Name:

Email:

Location:

URL:

Remember my personal information

Notify me of follow-up comments?

advertisement.gif (61x7 -- 0 bytes)
 

Are you a Doctor, Pharmacist, PA or a Nurse?

Join the Doctors Lounge online medical community

  • Editorial activities: Publish, peer review, edit online articles.

  • Ask a Doctor Teams: Respond to patient questions and discuss challenging presentations with other members.

Doctors Lounge Membership Application

 
     

 advertisement.gif (61x7 -- 0 bytes)

 

 

Useful Sites
MediLexicon
  Tools & Services: Follow DoctorsLounge on Twitter Follow us on Twitter | RSS News | Newsletter | Contact us
Copyright © 2001-2014
Doctors Lounge.
All rights reserved.

Medical Reference:
Diseases | Symptoms
Drugs | Labs | Procedures
Software | Tutorials

Advertising
Links | Humor
Forum Archive
CME | Conferences

Privacy Statement
Terms & Conditions
Editorial Board
About us | Email

This website is certified by Health On the Net Foundation. Click to verify. This site complies with the HONcode standard for trustworthy health information:
verify here.