Diode Laser Efficient, Safe for Tonsillotomy in Children

Last Updated: August 06, 2012.

 

Less intra-op bleeding, shorter operative time for 1,470 nm diode versus carbon dioxide laser

Share |

Comments: (0)

Tell-a-Friend

 

  Related
 
A fiber-guided 1,470 nm diode laser system is safe and effective for tonsillotomy in the treatment of obstructive tonsillar hypertrophy in children, according to a study published online July 26 in Lasers in Surgery and Medicine.

MONDAY, Aug. 6 (HealthDay News) -- A fiber-guided 1,470 nm diode laser system is safe and effective for tonsillotomy in the treatment of obstructive tonsillar hypertrophy in children, according to a study published online July 26 in Lasers in Surgery and Medicine.

To compare the effects of 1,470 nm diode laser and carbon dioxide laser for tonsillotomy, Miriam Havel, M.D., from the University of Munich, and colleagues conducted a trial with an intraindividual design. Twenty-one children (mean age, 6.3 years) underwent laser tonsillotomy for obstructive tonsillar hypertrophy. On one side, fiber-guided 1,470 nm diode laser (contact mode, 15 W power) was used, while carbon dioxide laser (12 W power) was used on the other side. A blinded physician assessed clinical findings and patients' symptoms at presentation and on days one, three, seven, 14, and 21, postoperatively.

The researchers found the mean operative treatment duration to be 2.7 min using 1,470 nm diode laser and 4.9 min using carbon dioxide laser. When using the 1,470 nm diode laser system, intraoperative bleeding and the frequency of bipolar forceps use for intraoperative bleeding control were significantly less. There was no difference in postoperative pain scores between the two laser treatments. During the three-week follow-up period, no infections, hemorrhages, or other complications occurred.

"Compared to the carbon dioxide laser, the 1,470 nm diode laser provides excellent cutting abilities combined with less intraoperative bleeding leading to shorter operation times," the authors write. "Taking into account that it is also well suited for coagulative endonasal applications, the 1,470 nm diode laser system offers a highly efficient alternative to the conventional carbon dioxide laser in clinical practice."

Abstract
Full Text (subscription or payment may be required)

Copyright © 2012 HealthDay. All rights reserved.


Previous: Complex Inheritance Usual in Vasovagal Syncope Next: Implantable Defibrillators Cut Out-of-Hospital Cardiac Arrests

Reader comments on this article are listed below. Review our comments policy.


Submit your opinion:

Name:

Email:

Location:

URL:

Remember my personal information

Notify me of follow-up comments?

advertisement.gif (61x7 -- 0 bytes)
 

Are you a Doctor, Pharmacist, PA or a Nurse?

Join the Doctors Lounge online medical community

  • Editorial activities: Publish, peer review, edit online articles.

  • Ask a Doctor Teams: Respond to patient questions and discuss challenging presentations with other members.

Doctors Lounge Membership Application

 
     
net

 advertisement.gif (61x7 -- 0 bytes)

 

 

Useful Sites
MediLexicon
  Tools & Services: Follow DoctorsLounge on Twitter Follow us on Twitter | RSS News | Newsletter | Contact us
Copyright © 2001-2014
Doctors Lounge.
All rights reserved.

Medical Reference:
Diseases | Symptoms
Drugs | Labs | Procedures
Software | Tutorials

Advertising
Links | Humor
Forum Archive
CME | Conferences

Privacy Statement
Terms & Conditions
Editorial Board
About us | Email

This website is certified by Health On the Net Foundation. Click to verify. This site complies with the HONcode standard for trustworthy health information:
verify here.