Create Account | Sign In: Author or Forum

 
 
News  |  Journals  |  Conferences  |  Blogs  |  Articles  |  Forums  |  Twitter    
 

 Headlines:

 

Category: ENT | Journal

Back to Journal Articles

pHDPE Implant Tied to Increased Infection Risk Post-Rhinoplasty

Last Updated: August 28, 2012.

 

Infections occur in one in five procedures in which porous high-density polyethylene implants are used

Share |

Comments: (0)

Tell-a-Friend

 

  Related
 
For patients undergoing rhinoplasty, the use of porous high-density polyethylene and expanded polytetrafluoroethylene implants is associated with increased risk of infection, according to a study published online Aug. 27 in the Archives of Facial Plastic Surgery.

TUESDAY, Aug. 28 (HealthDay News) -- For patients undergoing rhinoplasty, the use of porous high-density polyethylene (pHDPE) and expanded polytetrafluoroethylene (ePTFE) implants is associated with increased risk of infection, according to a study published online Aug. 27 in the Archives of Facial Plastic Surgery.

Andrew A. Winkler, M.D., from the University of Colorado in Denver, and colleagues examined the incidence of infection and extrusion of pHDPE and ePTFE implants used in 662 patients who underwent rhinoplasty procedures performed by three surgeons from 1999 to 2008.

The researchers found that the incidence of postoperative infection was 2.8 percent. Alloplastic material had been used in each case complicated by infection. In one of five rhinoplasty procedures in which pHDPE implants were used, infections occurred. The infection rate for patients in whom ePTFE was used alone was 5.3 percent. In 12 percent of patients in whom an alloplast was used during surgery, exposure developed. On bivariate analysis, sex, surgeon, purpose of procedure, current tobacco use, or history of cocaine use did not correlate with infection.

"In conclusion, the use of pHDPE and ePTFE implants in rhinoplasty is associated with an increased risk of postoperative infection," the authors write. "Caution is recommended when using pHDPE in rhinoplasty, especially as a columellar strut, although there may be situations in which the increased risk is acceptable."

One of the authors is a consultant for Ora Inc.

Abstract
Full Text (subscription or payment may be required)

Copyright © 2012 HealthDay. All rights reserved.


Previous: LABA Withdrawal Increases Asthma-Related Impairment Next: Five CSF Markers Differentiate Dementia, Parkinsonism

Reader comments on this article are listed below. Review our comments policy.


Submit your opinion:

Name:

Email:

Location:

URL:

Remember my personal information

Notify me of follow-up comments?

advertisement.gif (61x7 -- 0 bytes)
 

Are you a Doctor, Pharmacist, PA or a Nurse?

Join the Doctors Lounge online medical community

  • Editorial activities: Publish, peer review, edit online articles.

  • Ask a Doctor Teams: Respond to patient questions and discuss challenging presentations with other members.

Doctors Lounge Membership Application

 
     

 advertisement.gif (61x7 -- 0 bytes)

 

 

Useful Sites
MediLexicon
  Tools & Services: Follow DoctorsLounge on Twitter Follow us on Twitter | RSS News | Newsletter | Contact us
Copyright © 2001-2014
Doctors Lounge.
All rights reserved.

Medical Reference:
Diseases | Symptoms
Drugs | Labs | Procedures
Software | Tutorials

Advertising
Links | Humor
Forum Archive
CME | Conferences

Privacy Statement
Terms & Conditions
Editorial Board
About us | Email

This website is certified by Health On the Net Foundation. Click to verify. This site complies with the HONcode standard for trustworthy health information:
verify here.