ProDisc-C Device Doesn’t Change Facet Joint Pressures

Last Updated: October 03, 2012.

 

Implantation of device at C5 to C6 level increases angular rotations during sagittal bending

Share |

Comments: (0)

Tell-a-Friend

 

  Related
 
Local facet joint contact pressures are not significantly altered during sagittal bending after the implantation of a ProDisc-C device at the C5 to C6 level in cadaveric human cervical spines, according to a study published online Sept. 12 in The Spine Journal.

WEDNESDAY, Oct. 3 (HealthDay News) -- Local facet joint contact pressures are not significantly altered during sagittal bending after the implantation of a ProDisc-C device at the C5 to C6 level in cadaveric human cervical spines, according to a study published online Sept. 12 in The Spine Journal.

Joel A. Bauman, M.D., from the University of Pennsylvania in Philadelphia, and colleagues conducted a biomechanical study using seven C2 to T1 osteoligamentous cadaveric cervical spines instrumented with a transducer to measure the C5 to C6 facet pressure profiles during physiological sagittal bending. Pressure was measured before and after implantation of a ProDisc-C at the C5 to C6 level.

The researchers found that, following implantation, the mean C5 to C6 range of motion increased significantly, from 9.6 ± 5.1 degrees in the intact condition to 16.2 ± 3.6 degrees after implantation. During extension there was no significant difference in the facet contact pressure between the intact (64 ± 30 kPa) and implanted (44 ± 55 kPa) conditions, despite the changes in rotation. There was also no difference in facet pressure during flexion.

"Although implantation of a ProDisc-C arthroplasty device at the C5 to C6 level increases angular rotations, it does not significantly alter the local facet pressure at the index level in flexion or extension," the authors write. "Using a technique that preserves the capsular ligament, this study provides the first direct measurement of cervical facet pressure in a disc arthroplasty condition."

Several authors disclosed financial ties to the medical device industry.

Abstract
Full Text (subscription or payment may be required)

Copyright © 2012 HealthDay. All rights reserved.


Previous: Mexiletine Shows Promise for Rare Nondystrophic Myotonias Next: Cherry Intake Linked to Lower Risk of Recurrent Gout Attacks

Reader comments on this article are listed below. Review our comments policy.


Submit your opinion:

Name:

Email:

Location:

URL:

Remember my personal information

Notify me of follow-up comments?

advertisement.gif (61x7 -- 0 bytes)
 

Are you a Doctor, Pharmacist, PA or a Nurse?

Join the Doctors Lounge online medical community

  • Editorial activities: Publish, peer review, edit online articles.

Doctors Lounge Membership Application

 
     

 advertisement.gif (61x7 -- 0 bytes)

 

 

Useful Sites
MediLexicon
  Tools & Services: Follow DoctorsLounge on Twitter Follow us on Twitter | RSS News | Newsletter | Contact us
Copyright © 2001-2014
Doctors Lounge.
All rights reserved.

Medical Reference:
Diseases | Symptoms
Drugs | Labs | Procedures
Software | Tutorials

Advertising
Links | Humor
Forum Archive
CME | Conferences

Privacy Statement
Terms & Conditions
Editorial Board
About us | Email

This website is certified by Health On the Net Foundation. Click to verify. This site complies with the HONcode standard for trustworthy health information:
verify here.